WSRF- 50 , Radiografi/Fluorscopy 650 mA, Tube Toshiba.






 * RF#1 : This system is apical equipment that can control
                 radiographing and fluoroscopic condition in RF table.
 
 
Tube unit
H.T Cable
 Tube Voltage  150kVp  kVp Range  150kVp
 Focal Spot  0.6 - 1.2㎜
Image Intensifier
 Anode Heat  300KHU  Size  6inch / 9inch
Collimator (CM-W1)
Camera & Monitor
 Lightning  26 - 30sec, 100 - 160lux  Component Size  CCD Camera, 12”-17”
Tube Stand (TS-W1)
 * Option
 U/D mov. dls.  1300㎜  Ceiling Tube Suspended (TC-W1)
 L/R mov. dls.  2000㎜  Bucky Stand (BS-W1)
 Reve, angle  ±180˚  Bucky Table (BT-W1)
R/F Table (RFBT-W1)
 Touch Screen Type
 Tilting  +90˚ ~ -15˚  
 Dimension  2000L × 700W × 850H㎜
 
 
WSRF-50 system human body general Radiographic and Fluoroscopic are possible R/F system
by high frequency inverter mode and when Fluoroscopic is very convenient that user operates
because console that can control condition is attached on R/F table.
When Fluoroscopic, can use more conveniently if use ABS and AEC function
that is option function.

X-Ray Mobile , WON 300 mA, Korea, Tube Toshiba.



 
MODEL
WSM-300
WSM-300P
CONTROL UNIT
300mA at 100kVp
200mA at 125kVp
HIGH VOLTAGE
TRANSFORMER
High Frequency Inverter
X-RAY TUBE UNIT
ROTATING ANODE TYPE
TUBE
SUPPORT
UNIT
LOCKING
ELECTRO-MAGNETIC
LOCK FOR MOVEMENT
OF TRANSVERSE,
VERTICAL AND TUBE ROTATION
VERTICAL TRAVEL
770mm ~ 1770mm
TRANSVERSE TRAVEL
700mm ~ 870mm
ROTATION OF
VERTICAL COLUMN
±180˚AT EACH 90˚ POSITIONS MANUALLY
ROTATION OF
X-RAY TUBE UNIT
±180˚AT EACH 90˚ POSITIONS
ANGLE INDICATOR
CIRCULAR
COLLIMATOR
MANUAL DRIVE 24V/ 100W MORE THAN 160Lux
HIGH VOLTAGE CA BLE
3mx2 FEDERAL ENDS
MOBILE CART
LOCKING SYSTEM WITH CASSETTE BOX
POWER CONSUMPTION
SINGLE PHASC 220V,
50/60㎐ 30KVA
SINGLE PHASC 220V,
50/60㎐ 3KVA(PSU IN)
DIMENSIONS
MOBILE CART:600Wx1,065Lx1040Hm/ TUBE SUPPORT
UNIT:210Wx970Lx1,910Hm
NET WEIGHT
APPROX. 350kg


Brand : WON Solution
Type:    WSM-300, Mobile.
Negara Asal : Korea Selatan
Tube : Toshiba , Japan.
Garansi : 1 tahun
Document  Lngkap:  ( AKL/izin Edar , ISO, COO, LOA)
Informasi lebih lanjut : tentang harga,  brochure dll  e-mail : marketing_permana@yahoo.com
Atau kunjungi alamat Kantor kami di sini.






WSR 40, X-ray Stationary 500 mA, Korea , Tube Toshiba.







Tube unit
Bucky Table (BT-W1)  
 Focal size  1.0㎜ × 2.0㎜,
 0.6㎜× 1.2㎜
 Movement  Longitudinal, ±350㎜
 Transverse, ±150㎜
 Anode Heat Unit  140kHU, 300kHU  Table Dimensions  2000L×745W×710H
 Max kVp  125kVp, 150kVp  * OPTION
 Max mA  300㎃/ 500㎃/ 600㎃
Bucky Stand (BS-W1)
Collimator (CM-W1)
 Dimension  585W × 585D × 1900H㎜
 Lightning  26 - 30sec, 100 -  160lux  Grid : Standard  Bucky 85LPI 8:1 fd=40- 72”
Tube Stand (TS-W1)
Ceiling Tube Suspended (TC-W1)
 Left/Right moving
 available
 1,800㎜ more  Movement  Up/Down,1200㎜
 Longitudinal, 2950㎜ /

 Transverse, 1750㎜
 Total height  2,100㎜
 Stand arm swing
 angle
 ±90˚  Arm Angle  ±180˚
 

Rabu, 06 April 2011

X-Ray Mednif 30 mA, China








Brand : mednif,china
Type: mobile
Condition : second
Guarantee: 3 months
Ready stock: 1 Unit

Harga ;     ( Terjual)

Selasa, 22 Maret 2011

General X-Ray Shimadzu


Type of Equipment:  General X-Ray Room
Make & Model:  Shimadzu UD150L-RII
Year of Manufacture: 1999
Serial Number:  262060708
X-Ray Tube Serial Number: 26775
Tube Manufacturer: Shimadzu
Maximum kVp: 130kVp
Maximum mA:  500mA
Power in kW: 50 kW
Frequency:  Medium frequency
Is the table height adjustable: Yes
Is the system tube stand or ceiling suspension:  Ceiling Tube Mount
 Price : Rp 200.000.000,-  ( TERJUAL)

X-Ray Stationary Hyundai



Brand : Hyundai.
Model : HD-300 R-AD
Type : Satationary, 300 mA.
Tube : Toshiba.
Condition ; Second
Ready Stock : 1 Unit.
Guarantee : 6 Month.

Price : Rp 130.000.000,- (TERJUAL)

Rabu, 16 Maret 2011

CR-ADC Solo Digitizer AGFA


Digitizer Type:
Single cassette feed
Dimensions:
(w × d × h)
18" ×30" ×56"
(Depth29" at cassette-slot)
Weight:
Approx. 463 lbs.
Power:
230 – 240 V/50 – 60 Hz
standby 230 W, max. 1610
W, 16 A fuse (USA)
120 V/60 Hz (USA) standby
216 W, max.
1440 W, 15 A fuse
100 V/60 Hz (Japan)
standby 220 W, max.
1500 W, 15 A fuse
Throughput:
60 plates/h 8" × 10''
(18 × 24 cm)
50 plates/h 14" × 17''
(35 × 43 cm)
35 plates/h 14" × 17'' HR
(35 × 43 cm HR)
Accepted Cassette Sizes:
14" × 17'' (35 × 43 cm)
14" × 14'' (35 × 35 cm)
10" × 12'' (24 × 30 cm)
6" × 12'' (15 × 30 cm)
8" × 10'' (18 × 24 cm)
Grayscale Resolution:
Data acquisition:

12 bits/pixel
Spatial Resolution:
Reading sampling frequency:

14" × 17" (35 × 43 cm):
6 pixels/mm
14" × 14" (35 × 35 cm):
6 pixels/mm
14" × 17" HR (35 × 43 cm
HR): 9 pixels/mm (option)
14" × 14" HR (35 × 35 cm
HR): 9 pixels/mm (option)
10" × 12'' (24 × 30 cm):
9 pixels/mm
8" × 10'' (18 × 24 cm):
9 pixels/mm
6" × 12'' (15 × 30 cm):
9 pixels/mm
Output to processor:
12 bits/pixel
Pixel Matrix Size:
14" × 17'' (35 × 43 cm):
2048 × 2494
14" × 17'' HR (35 × 43 cm
HR): 3062 × 3730
14" × 14'' (35 × 35 cm):
2048 × 2048
14" × 14'' HR (35 × 35 cm
HR): 3062 × 3062
8" × 17'' (21 × 43 cm)
(partial scan of 14" × 17''
(35 × 43 cm) cassette):
1778 × 3732
10" × 12'' (24 × 30 cm):
2040 × 2570
8" × 10'' (18 × 24 cm):
1514 × 2044
6" × 12'' (15 × 30 cm):
1248 × 2570
Display:
Machine status and error
conditions, emergency keys
Environmental
Conditions:
Temperature: 60 – 85°F
(15 – 30°C)
Rate of temperature change:
0.9°F/min.
Humidity: 15 – 75% RH
Magnetic fields: max. 12.60
μT (in conformance with EN
61000-4-8: level 3), 10 A/m
Environmental Effects:
Noise level: max. 65 dB (A)
Heat dissipation: standby
230 W maximum 1610 W
Safety Standards:
EN 60950, 60825-1: 1994,
60601-1-2, UL 1950
CSA C22.2 No 950
DHHS/FDA 21 CFR parts
1040.10 and 1040.11
EEC 89/336, 93/42, 73/23,
89/392
Approvals:
TüV, GS, CE, UL, CUL
Price : Rp 250.000.000,- ( TERJUAL)